Atmospheric Combi Gas Boiler with Gas Voltage Water Pressure Adaptive Technology

After-sales Service: 1 Year
Warranty: 1 Year
Certification: ISO9001
Heating Type: Nature Gas
Open Therm: Optional
Structure: Plate Exchange/Bithermic

Products Details

Basic Info.

Model NO.
36kw
Water Circuit
Plastic / Copper
Low Pressure Start
Yes
Low Voltage Start
Yes
Transport Package
Cartton
Specification
16kw-24kw
Trademark
OEM
Origin
China
HS Code
8403101000
Production Capacity
240, 000PCS/Year

Product Description

Atmospheric Combi Gas Boiler with Gas Voltage Water Pressure Adaptive Technology 
Atmospheric Combi Gas Boiler with Gas Voltage Water Pressure Adaptive Technology
Atmospheric Combi Gas Boiler with Gas Voltage Water Pressure Adaptive Technology
Atmospheric Combi Gas Boiler with Gas Voltage Water Pressure Adaptive Technology
Model 18kw 20kw 24kw 28kw 32kw 36kw 40kw 45kw
Gas Type / Natural gas(12T)
Gas Pressure Pa 2000
Rated max./min. heat load of CH kw 18/6.3 20/7 24/8.5 28/9.8 32/11.2 36/12.6 40/14 45/16.5
Rated max./min. heat output of CH kw 16.5/5.5 18/6.1 22/7.2 25.5/8.3 29.3/9.5 32.4/10.7 36/11.9 40.9/14.3
Rated heat load of DHW kw 18 20 24 28 32 36 40 45
Rated min. heat load of DHW kw 3.1 3.1 3.5 3.9 4.5 5 5.6 6.3
Rated min. heat load of DHW kw 2.6 2.6 3 3.3 3.9 4.2 4.7 5.3
Ignition power kw 10 12 14.4 16.8 19.2 21 21.6 24.5
Thermal Efficiency (At rated input power) % 92 92 92 92 92 92 92 92
Thermal Efficiency (At 30% input power) % 90 90 90 90 90 90 90 90
Max. water pressure of CH system MPa 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Min./Max. CH Water Temperature °C 30/80 30/80 30/80 30/80 30/80 30/80 30/80 30/80
CH Water Temp. Adjustment Range (Radiator) °C 30-80 30-80 30-80 30-80 30-80 30-80 30-80 30-80
CH Water Temp. Adjustment Range (Floor Heating) °C 30-60 30-60 30-60 30-60 30-60 30-60 30-60 30-60
Max./Min. DWH Water pressure MPa 0.8/0.025 0.8/0.025 0.8/0.025 0.8/0.025 0.8/0.025 0.8/0.025 0.8/0.025 0.8/0.025
Min. flow of DHW kg/min 3 3 3 3 3 3 3 3
Rated Water Capacity (Δt=25ºC) kg/min 8.3 10.3 12.6 14.6 16.8 18.6 20.6 23.2
Expansion Tank Volume L 6.5-8 6.5-8 6.5-8 6.5-8 8-10 8-10 8-10 8-10
Reference gas consumption (NG 12T) m3/h 0.65-2 0.75-2.15 0.91-2.58 1.05-3 1.2-3.43 1.33-3.81 1.58-4.28 1.72-4.65
Heating Area m2 65-110 70-120 90-150 120-200 160-260 200-310 250-360 290-420

Atmospheric Combi Gas Boiler with Gas Voltage Water Pressure Adaptive Technology
Atmospheric Combi Gas Boiler with Gas Voltage Water Pressure Adaptive Technology
We specialize in the production of wall-hung boilers, fully premixed low-NOx commercial boilers, intelligent controllers, etc. We have passed the ISO9001 quality management system certification, and use frequency conversion technology and low nitrogen technology to improve the product efficiency of conventional wall-hung boilers and fully premixed condensing boilers.
 
 2 fully automatic production lines, equipped with test benches conforming to international standards and national laboratories, apply MES, SRM, WMS system for digital information management ,with a daily production capacity of 800 units. 
 
Atmospheric Combi Gas Boiler with Gas Voltage Water Pressure Adaptive Technology
Atmospheric Combi Gas Boiler with Gas Voltage Water Pressure Adaptive TechnologyAtmospheric Combi Gas Boiler with Gas Voltage Water Pressure Adaptive Technology
Atmospheric Combi Gas Boiler with Gas Voltage Water Pressure Adaptive Technology
 
       

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours