- Overview
- Product Description
- Product features
- Test standard
- Product Parameters
Basic Info.
Product Description
Environment Climate Test Chamber
New Energy Vehicles Auto Parts 1000L -80 degrees 10%RH High Low Temperature Humidity Cycle Environment Climate Test Chamber, is used for material performance test under different environment, such as heat, cold, moisture, heat and moisture, mainly applied in electronics, electrical appliances, mobile, communications, instruments, vehicles, plastic products, metals, food, chemicals, building materials, medical, aerospace and other industries.
Definition of new energy vehicles:
New energy vehicles is also known as alternative fuel vehicles, include pure electric vehicles, fuel cell electric vehicles and other vehicles that use all non-petroleum fuels, as well as hybrid electric vehicles, ethanol gasoline vehicles and some other vehicles that use non-petroleum fuels. All existing new energy vehicles are included in this concept, which are divided into six categories: hybrid vehicles, pure electric vehicles, fuel cell vehicles, alcohol ether fuel vehicles, natural gas vehicles, etc.
New energy vehicle reliability test: including climate environment test (including high and low temperature storage test, high and low temperature operation test, warm storage and operation test, temperature cycle test, thermal shock test, high and low temperature limit test, IP protection test, salt spray test) and mechanical environmental test (including vibration, drop test). Guangdong Yuanyao Test Equipment Co., Ltd. can provide this series of reliability environmental testing equipment, providing one-stop testing equipment solutions for new energy vehicles and new energy auto parts customers.
1.Samwontcech Korea controller, support 5 languages in terface.
2.Automatic water filling(optional).3.Access to PC remote control and monitoring.
4.Customization services.
5.With national patents
GBT18488.1-2006 Electric Motors and Controllers for Electric Vehicles, Part 1: Technical Conditions;
GBT18488.2-2006 Electric motor and its controller for electric vehicles, Part 2: Test methods;
ISO 16750-2006 Road vehicles: Environmental conditions and tests for electrical and electronic equipment;
ISO 20653-2006 Protection class of road vehicles, protection of electrical equipment against foreign objects, water and contact;
QCT-413-2002 Basic technical conditions for automotive electrical equipment;
GBT 2423.01-2008 Environmental Testing of Electrical and Electronic Products Part 2 Test Methods Test A: Low temperature;
GBT 2423.02-2008 Environmental testing of electrical and electronic products Part 2 Test methods Test B: high temperature;
GBT 2423.03-2006 Environmental Testing of Electrical and Electronic Products Part 2 Test Methods Test Cab: Constant Damp Heat Test;
GBT 2423.04-2008 Environmental testing of electrical and electronic products Part 2 Test methods Test Db: alternating damp heat (12h+12h cycle);
GBT 2423.17-2008 Environmental testing of electrical and electronic products Part 2 Test methods Test Ka Salt spray;
GBT 2423.18-2012 Environmental testing Part 2 Test methods Test Kb: salt spray, alternating (sodium chloride solution);
GBT 2423.37-2006 Environmental testing of electrical and electronic products - Part 2: Test methods Test L Sand and dust test;
GBT 2423.34-2012 Environmental Testing Part 2 Test Methods Test ZAD: Temperature and humidity combined cycle test;
GBT 2423.56-2006 Environmental testing of electrical and electronic products - Part 2: Test methods - Test Fh : Broadband random vibration (digital control) and guideline tests.
Put the test sample into the temperature chamber, let the temperature in the chamber rise (1°C/min) to 105°C or 85°C (water-cooled model 105°C, air-cooled to 85°C), and keep for 48h.
Lower the temperature (1°C/min) to normal atmospheric conditions, and recover for 1 hour under these conditions. The cooling time in the chamber is not included in the recovery time.
Test reference curve:
Low temperature storage condition test:
Put the test sample into the chamber, make the temperature in the chamber drop to -40°C, keep it for 24h, and the temperature rise and fall rate is 1°C/min. Raise the temperature to normal atmospheric conditions, and recover under these conditions for 1 hour. The heating time in the box is not included in the recovery time.
Test reference curve:
Model | YTH-080 | YTH-150 | YTH-225 | YTH-408 | YTH-800 | YTH-1000 |
Inner chamber size W×H×D(cm) | 40×50×50 | 50×60×50 | 50×75×50 | 80×85×60 | 100×100×80 | 100×100×100 |
Exterior chamber size W×H×D(cm) | 60×172×120 | 70×174×130 | 70×172×181 | 100×182×197 | 120×197×197 | 120×197×217 |
Testing temperature range | -80ºC, -70ºC,-60ºC,-40ºC,-20ºC,0ºC~150ºC,Other temperature can be customized | |||||
Testing humidity range | 20%RH~98%RH(Low humidity 10%RH~98%RH or 5%RH can be customized) | |||||
Temp.humi.fluctuation | ±0.5ºC;±0.5%RH | |||||
Temp.humi.uniformity | ±2ºC;±3% empty loading after stablize for 30mins ±2ºC;±3%RH | |||||
Temp.humi.resolution | 0.01ºC;0.1%RH | |||||
Heating&cooling time ºC/min | Heat-up:3ºC/min(average),cool-down:1ºC/min(average) | |||||
Exterior chamber material | Cold rolled plate + Powder coating | |||||
Interior chamber material | SUS#304 Stainless steel | |||||
Insulation material | PU | |||||
Circulation system | Centrifugal fan air circulation system | |||||
Heating system | SUS# Stainless steel high-speed heater | |||||
Humidification system | Electrothermal steam humidification | |||||
Dehumidifying | ADP critical dew point cooling / dehumidifying method | |||||
Refrigeration system | Compressor + Finned evaporator + Air(Water) cooling condenser | |||||
Controlling system | Touch screen controller | |||||
Other components | Vacuum glass observation window | |||||
Test hole(50mm) | ||||||
Controller status indicator | ||||||
View light | ||||||
Compartment shelf (2 freely adjustable) | ||||||
Safety protection device | Overheat protection circuit breaker | |||||
Humidification system overheat protection | ||||||
Compressor overload protection | ||||||
Control system overload protection | ||||||
overload indicator | ||||||
Phase sequence protection | ||||||
Water shortage protection | ||||||
High voltage and low voltage protection | ||||||
Over temperature protection | ||||||
Water supply delay protection | ||||||
Fan overcurrent protection | ||||||
Power supply | AC 1ψ220V;3ψ380V 60/50Hz | |||||
Customization service | Non-standard or special requirements are all welcome |
More detail of High Low Temperature Humidity Cycle Environment Climate Test Chamber
Production Line:
We have independent workshops, they are consist of material bending and welding area, machine assemble area, electric system area, cooling system area ,testing and finished product area.
We produce in strict accordance with international safety standard.
Many stock spare parts in warehouse ensure customer can get soon when they need.
Yuanyao profile