- Overview
- Specification
- Company Profile
- FAQ
Basic Info.
Model NO.
ORCL-STUC
Brand & Printed
Customized
Usage
Single-Use
Size
Fr8-Fr24
Quality Certification
CE/ISO13485
Color
Multicolor
Service
OEM/ODM
Properties
Medical Polymer Materials & Products
Disinfecting Type
EOS
Safety Standard
En166
Instrument Classification
Class II
Product Name
Disposable Silicone Thermometric Urethral Catheter
Shelf Life
3 Years
Application
ICU/Urology Surgery
Stock
No
Certificate
ISO13485 /CE
Transport Package
1 PC/Polybag and 500PCS Per Carton
Trademark
ORCL or OEM
Origin
Guangdong, China
HS Code
9018390000
Production Capacity
10000 Piece/Pieces Per Day
Product Description
Product name | Disposable Silicone Foley Catheter With Temperature Sensor Thermometric Urethral Catheter |
Size | Fr8-Fr22 |
Material | Medical Silicone |
Type | 2-way |
Certificate | CE&ISO13485 |
Application | ICU/Urology Surgery |
MOQ | 5000 pcs |
Color | Multicolor |
Feature | Bladder temperature measurment |
Sterile | EOS |
Port | FOB Guangzhou |
Sample Time | 1-3working days |
Payment method | T/T, Alibaba Trade Assurance,Western Union |
Shipment | Express;Air Transport;Shipping |
product description:
It is made of medical silica gel and has good biocompatibility.It is used for medical department.When catheterization or drainage
is used,the bladder temperature can be detected simultaneously.Our foley catheter with temperature sensor is designed to be used
before, during, and after surgery to monitor core body temperature. and is available with long term placement. We also offer a
various kind of temperature extension cable for different indication.
is used,the bladder temperature can be detected simultaneously.Our foley catheter with temperature sensor is designed to be used
before, during, and after surgery to monitor core body temperature. and is available with long term placement. We also offer a
various kind of temperature extension cable for different indication.
Function
Thermometers Urethral Catheter are often used as the best thermometers to measure bladder temperature in patients because of their
characteristics of non-invasive, rapid, accurate, safe and simple operation.
characteristics of non-invasive, rapid, accurate, safe and simple operation.
Feature:
1. Made from 100% medical grade silicone
2. Good for long term placement
3. X-ray detective line through the catheter.
5. Color-coded for visualization of size
6. Single use only.
7. CE, ISO 13485 certificates
8.Monitor the temperature of bladder during the conventional catheterization.
9.Temperature range: 25-45 °C, accuracy ± 0.1 °C
10.The balloon filling amount can be customized according to customer requirements.
2. Good for long term placement
3. X-ray detective line through the catheter.
5. Color-coded for visualization of size
6. Single use only.
7. CE, ISO 13485 certificates
8.Monitor the temperature of bladder during the conventional catheterization.
9.Temperature range: 25-45 °C, accuracy ± 0.1 °C
10.The balloon filling amount can be customized according to customer requirements.
(Fr/Ch) | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 |
Capacity [ml] | 3-5 | 5-10 | 5-10 | 5-15 | 10-30 | 10-30 | 10-30 | 10-30 | 10-30 |
Length(mm) | 300 | 300 | 400 | 400 | 400 | 400 | 400 | 400 | 400 |
Use method:
1.Disassemble the catheter into a single initial package to check whether the appearance quality of the catheter meets the
requirements
2.Evenly lube the tip and body of the catheter (petroleum-based lube is not allowed)
3.Carefully insert the tip of the catheter into the bladder (to determine whether the tip of the catheter is inserted into the
bladder by the flow of urine), then insert about 3cm to ensure that the balloon is also inserted into the bladder
4.Inject sterilized distilled water or normal saline into the balloon using a syringe without a needle
5.Connect the connector of the temperature measuring chamber to the monitor to read the temperature
6.After the use of the catheter, the filling conical interface can be cut off to drain the water from the balloon and the catheter
can be pulled out
requirements
2.Evenly lube the tip and body of the catheter (petroleum-based lube is not allowed)
3.Carefully insert the tip of the catheter into the bladder (to determine whether the tip of the catheter is inserted into the
bladder by the flow of urine), then insert about 3cm to ensure that the balloon is also inserted into the bladder
4.Inject sterilized distilled water or normal saline into the balloon using a syringe without a needle
5.Connect the connector of the temperature measuring chamber to the monitor to read the temperature
6.After the use of the catheter, the filling conical interface can be cut off to drain the water from the balloon and the catheter
can be pulled out
Attention:
This product is not allowed to remain in the body for more than 28 days.Do not pull the cable during use
Q1. Can I have a sample order? A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable. Q2. What about the lead time? A: Sample needs 3-5 days, mass production time needs 2-4 weeks for order quantity more than10,000 pcs Q3. Do you have any MOQ limit for this item? A: Low MOQ, 1pc for sample checking is available Q4. How do you ship the goods and how long does it take to arrive? A: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping also optional. Q5. How to proceed an order for dedical consumables? A: Firstly let us know your requirements or application. Secondly We quote according to your requirements or our suggestions. Thirdly customer confirms the samples and places deposit for formal order. Fourthly We arrange the production. Q6. Is it OK to print my logo on package? A: Yes. Please inform us formally before our production and confirm the design firstly based on our sample.